[Register][Forgot password]
Sales Hotline
Search Inquire No.
Product List
.:Product Show:.

AAM-900: Atomization Disinfectant Machinewash

Channels: DMX 512,Wire and Remote Contro
Body Size:370*240*370 mm
N.W: 4 Kg
Class: Smoke machine Effect Machine
.:Feature:.

Power Supply: 90-240V Frequency: 50-60Hz Power: 1500W Control: DMX 512,Wire and Remote Control Fuse: 10A Tank Capacity: 5 Ltr Warm Up Time: 3-5 mins Smoke Coverage: 12 meters Smoke Output: 20000cu.ft/min Body Color: Silver Applicable Places: Stage, DJ bars, hotel, KTV, theatre, performance, nightclubs, concerts etc. Packing Size: 540x320x270 mm G.W.:/NW 6.5 kg/5KGS

Power Supply: 90-240V
Frequency: 50-60Hz
Power: 1500W
Control: DMX 512,Wire and Remote Control
Fuse: 10A
Tank Capacity: 5 Ltr
Warm Up Time: 3-5 mins
Smoke Coverage: 12 meters
Smoke Output: 20000cu.ft/min
Body Color: Silver
Applicable Places: Stage, DJ bars, hotel, KTV, theatre, performance, nightclubs, concerts etc.
Packing Size: 540x320x270 mm
G.W.:/NW 6.5 kg/5KGS
Disinfection time continuous disinfection

 
Instructions for use
The indoor atomization and anti-bacterial machine (atomization machine) connected to 220V power supply, open the warm-up for 3 minutes, to be the handle button light,said atomization machine can work.
Handle operation: press the handle to the button button, atomization machine work;release the handle button, atomization machine to stop working.
 
Working principle
Indoor atomization and antimicrobial (atomization machine) The use of non-steam dry smoke to disinfect the ingredients to the car has a smell of the part. Which play a decomposition of odor, sterilization deodorant effect. And with a scent to purify the air.
Automatically smoke, the bike to purify the smoke 5-8 minutes, and then open the car within 10 minutes after the smoke adsorption is completed, and then open the door to feel healthy and fresh air.
 
Spraying antibacterial disinfection machine steps
Step 1 : start the car, the car is inside the cycle, the wind speed is 3 files, and the cold air is opened. Power on the machine into the front passenger seat row and open the red switch button on the back of the machine.
Step 2: Wait for 5 minutes for preheating, wait until the handle light is on. Then press the timer switch (4 ml to 100 ml of potion. Please set 4 or more below 80 ml.)
The third step: atomization for about 3 to 5 minutes, the liquid medicine is sprayed off the machine, take out the machine, continue the inner circulation for about 15 minutes, let it fully absorb.
The fourth step: ventilate, cycle outside for 3 minutes, the entire construction is completed, check the switch off and deliver.
 
Tips
After the machine is finished, it is best to use a clear water spray. Keep the machine piping clean and unobstructed to prevent blockages from affecting machine operation.

 Cleaning function
Connect the machine to the power supply, press the black switch to the left cleaning position, turn the timing knob to about 2 steps, and rinse the machine pipe with clean water or clean tap water.
  Hits:6244   Date: 2020-4-27   PrintClose